RSM approach for modeling and optimization of designing parameters for inclined fins of solar air heater

JavaScript is disabled on your browser. Please enable JavaScript to use all the features on this page.

Highlights

RSM was applied to analyze the results of finite volume method and to optimize the process parameters of SAH.

A significant heat transfer enhancement was observed for a SAH having inclined fins on the underside of the absorber plate.

The Nusselt number increases with the increase in Re. Whereas, friction factor decreases as the Re increases in all cases.

A better thermal performance of inclined fins in terms of THPP has been achieved compared to the previous work.

Abstract

In the present study, a simulation and response surface methodology (RSM) combined approach has been applied to investigate the thermal and thermo-hydraulic performance parameter (THPP) of solar air heater (SAH) with inclined fins. CFD based software (ANSYS Fluent v16.1) is used to simulate the SAH. RNG k−ε turbulence model was selected to carry out a two-dimensional simulation modeling. Moreover, RSM is applied to analyze the results of finite volume method and to optimize the process parameters of SAH. A numerical model describing the heat transfer characteristics of SAH having inclined fins has been developed and employed to study the effects of various design of fins on the average Nusselt number, fiction factor as well as THPP. The study covered different length of fin in the range of 1.5–2.5 mm, different slant angle (α) of fin in the range of 30°–60°, different pitch (P) of fin in the range of 15–25 mm, and a range of 4000–24,000 for the Reynolds numbers. Based on results of the model, the optimized values of design parameters for the optimal operation of SAH to provide the optimal THPP of 1.928 were found to be; length of fin = 1.52 mm, the pitch of fin = 19.04 mm, slant angle = 49° and Reynolds number at 18243.5. According to the optimized values of design parameters, the enhancement ratio of Nusselt number and friction factor were found to be 2.53 and 2.22, respectively. Finally, the thermal performance of the proposed inclined fin in terms of THPP was compared to other roughness geometries, such as circle (THPP = 1.65), square-sectioned (THPP = 1.80) and L-shaped (THPP = 1.90). Accordingly, a better THPP of 1.928 was observed for the current study.

Keywords

Solar air heater

Inclined fins

CFD

RSM

© 2019 Elsevier Ltd. All rights reserved.

Be the first to comment

Leave a Reply

Your email address will not be published.


*